guoyujie
2025-08-21 174a6b7bc81a21f8cf950760d3e17fd5f4b7c4dd
north-glass-erp/src/main/resources/mapper/pp/GlassOptimize.xml
@@ -196,13 +196,22 @@
             op.project_name,
             0 as patchState,
             c.rack AS rackNo,
             0 as layoutId
             0 as heatLayoutId,
             d.process,
             o.order_id AS orderNo,
             o.customer_name AS customerName,
             o.processing_note AS processingNote,
             o.project AS projectName,
             od.product_name AS productName,
             od.building_number AS buildingNumber
         FROM
             pp.flow_card c
                 LEFT JOIN sd.order_glass_detail d ON c.order_id = d.order_id
                 AND c.order_number = d.order_number
                 AND c.technology_number = d.technology_number
                 INNER JOIN pp.optimize_project AS op ON op.project_no = c.project_no
                 LEFT JOIN sd.ORDER o ON o.order_id = c.order_id
                 LEFT JOIN order_detail od ON c.order_id = od.order_id
         WHERE
             c.project_no IS NOT NULL
           and c.project_no = #{projectNo}
@@ -226,7 +235,14 @@
                op.project_name,
                1 as patch_state,
                a.id as rackNo,
                0 as layoutId
                0 as heatLayoutId,
                d.process,
                o.order_id AS orderNo,
                o.customer_name AS customerName,
                o.processing_note AS processingNote,
                o.project AS projectName,
                od.product_name AS productName,
                od.building_number AS buildingNumber
            FROM
                pp.patch_log c
                    LEFT JOIN sd.order_glass_detail d ON c.order_id = d.order_id
@@ -234,6 +250,8 @@
                    AND c.technology_number = d.technology_number
                    INNER JOIN pp.optimize_project AS op ON op.project_no = c.project_no
                    LEFT JOIN pp.flow_card fc ON c.process_id = fc.process_id and fc.technology_number=c.technology_number
                    LEFT JOIN sd.ORDER o ON o.order_id = c.order_id
                    LEFT JOIN order_detail od ON c.order_id = od.order_id
                    left join
                (select (@row_number := @row_number + 1) as id,process_id as process_id,technology_number as technology_number from (select process_id,technology_number from pp.flow_card tt where project_no =#{projectNo} group by process_id,technology_number) tt,(select @row_number := 0) as t) a
                on a.process_id=c.process_id and a.technology_number=c.technology_number
@@ -311,7 +329,7 @@
    <select id="computeAndOptimization">
        SELECT
            c.rack AS rackNo,
            h.layout_id as layoutId,
            h.layout_id as heatLayoutId,
            h.width AS width,
            h.height AS height,
            count( 1 ) AS quantity,
@@ -323,7 +341,14 @@
            c.order_number,
            h.order_sort AS orderSort,
            d.icon AS markIcon,
            h.patch_state  AS patchState
            h.patch_state  AS patchState,
            d.process,
            o.order_id AS orderNo,
            o.customer_name AS customerName,
            o.processing_note AS processingNote,
            o.project AS projectName,
            od.product_name AS productName,
            od.building_number AS buildingNumber
        from
            pp.`optimize_heat_detail` h
                LEFT JOIN pp.flow_card c ON h.process_id = c.process_id
@@ -332,6 +357,8 @@
                LEFT JOIN sd.order_glass_detail d ON c.order_id = d.order_id
                AND c.order_number = d.order_number
                AND c.technology_number = d.technology_number
                LEFT JOIN sd.order o on  o.order_id = c.order_id
                LEFT JOIN order_detail od on  c.order_id = od.order_id
        WHERE
            h.project_no = #{projectNo}
        GROUP BY